Microsoft has just updated the following KB Article:

System Center 2012 Configuration Manager Software Center does not launch on a Windows XP client if Terminal Services is disabled

Symptoms:
When starting Software Center on a Windows XP client you receive the error “There is a problem showing the current status”. When clicking More Information you see error code 0x80041001.

In ccmsdkprovider.log you will also see the following error:

<![LOG[Failed to get domain name from WTS session 0, 0x800706a6]LOG]!><time=”15:50:26.121-720″ date=”04-23-2012″ component=”CCMSDKProvider” context=”” type=”3″ thread=”264″ file=”ccmsdkprovider.cpp:3785″>
<![LOG[GetUserCapability failed with error code 0x800706a6]LOG]!><time=”15:50:26.121-720″ date=”04-23-2012″ component=”CCMSDKProvider” context=”” type=”3″ thread=”264″ file=”ccmsdkprovider.cpp:3266″>

Error 800706a6 means that the RPC binding handle is invalid.

GetUserCapability calls Windows Terminal Server (WTS) functions to query session information for the Remote Desktop Session Host (RD Session Host) server. It can be used to query session information on local and remote desktop session host servers.

If Terminal Services is not running, calls to WTS functions fail.

Full details at:
http://support.microsoft.com/kb/2713471

 